UHV Sample Holders

Widest range of UHV sample holders with electrical, heating and cooling options.

Our UHV sample holders offer the widest possible range of sample heating, sample cooling and sample electrical conditions to address every conceivable surface science application.

Since all of our models are based around one standard design (the PTS), all critical parts across the range can be replaced without breaking vacuum.

Below are just some examples. The range is continually updated and the latest details can be downloaded here; icon UHV Sample Holders

You may also be interested in our resistive UHV sample heater and e-beam UHV sample heater power supplies.

UHV Sample Holders Receiving Station

PTS UHV Sample Holders Receiving Station

  • 1 inch sample size
  • Very high cooling efficiency down to 88k (LN2) and also LHe
  • Heating by direct/indirect/e-beam methods
  • 6 electrical contacts (heating/temp meas/bias)
  • Quartz balance/Faraday cup/high pressure/powders/IR & UV transmission mode
  • Adapters for e.g. Omicron sample holders
New! See a video of the manipulation & transfer of our SPM holder

PTS UHV Sample Holders Bottom View

  • Temperature range 90 to 2300Kwith direct or indirect heating
  • High pressure reactor versions for heating in reactive gas atmospheres to 1200K
  • With integrated quartz balance
  • With integrated Faraday cup
  • Adapters for other sample holders, e.g. Omicron & STMs
  • Heating & cooling for transmission spectroscopy (IR and UV)
  • Integrated charge compensation

UHV Sample Holders Schematic



 UHV Sample Holders Collection

UHV Sample Holders - PTS StandardPTS Standard: Base model sample holder for easy sample mounting and with with sample bias function.

PTS 1000 HC: Sample holder made from molybdenum with indirect sample heating up to 1000°C and cooling down to –170°C.UHV Sample Holder - PTS 1000HC
UHV Sample Holder - PTS 1200HCPTS 1200 HC: UHV sample holder with electron beam heating up to 1200°C and cooling down to –180°C.

PTS 2000 HC: UHV sample holder with electron beam heating up to 2000°C.UHV Sample Holder - PTS 2000HC
UHV Sample Holder - PTS CleavHCPTS Cleave HC: UHV sample holder made from copper with indirect sample heating up to 600°C and cooling down to –180°C, dedicated for cleaver chamber.

PTS Quartz: UHV sample holder with integrated quartz balance.UHV Sample Holder - PTS Quartz
UHV Sample Holder - PTS OmicronPTS OMC H: Sample holder made from molybdenum with indirect sample heating up to 1000°C and cooling down to –160°C with adapter to Omicron sample holder.

PTS 1200 RHK: Sample holder dedicated for SPM measurements with heating up to 1200°C (with EB) or 500°C (without EB) and cooling down to –170°C.

UHV Sample Holder - PTS 1300RHK

 Related products: ion source surface cleaning, plasma cleaning units, TPD mass spectrometers


 